| 505 Batch Controllers |
Datasheet |
Manual |
|
pulse/frequency input-volume. field, panel or flameproof [EExd IIB T6] mounting, single flowmeter input, dual relay outputs, modbus output, logging, ticket printing, pulse output, analogue output, 12-28vdc, 110-240vac supply. |
|
|
|
analogue input - volume |
|
|
|
pulse/frequency input - mass |
|
|
|
analogue input - mass |
|
|
| 505 Flow Computers - Liquids |
Datasheet |
Manual |
|
pulse/frequency input-volume. field, panel or flameproof [EExd IIB T6] mounting, single flowmeter input, dual relay outputs, modbus output, logging, ticket printing, pulse output, analogue output, 12-28vdc, 110-240vac supply. |
|
|
|
analogue input - volume |
|
|
|
pulse/frequency input - mass |
|
|
|
analogue input - mass |
|
|
| |
|
generic density, pulse/frequency flow input, analogue input for temperature, density, pressure or unitless value. |
|
|
| |
|
open channel measurement, frequency flowmeters / analogue level sensors |
|
|
| 505 Level Monitor |
Datasheet |
Manual |
|
analogue input, field, panel or flameproof mounting (EExd IIB T6), 20 point strapping table, dual relay outputs, modbus output, logging, ticket printing, analogue output, 12-28vdc, 110-240vac supply. |
|
|
| 515 Batch Controllers |
Datasheet |
Manual |
|
pulse/frequency input - volume. field, panel or flameproof [EExd IIB T6] mounting, single flowmeter input, dual relay outputs, 4-20mA output for flow control, modbus output, logging, ticket printing, pulse output, analogue output, alarm outputs, 12-28vdc, 110-240vac supply. |
|
|
|
analogue input - volume |
|
|
|
pulse/frequency input - mass |
|
|
|
analogue input - mass |
|
|
| |
|
pulse/frequency input - volume. field, panel or flameproof [EExd IIB T6] mounting, dual flowmeter inputs, dual relay outputs, 4-20mA output for dual stream blend control, modbus output, logging, ticket printing, pulse output, analogue output, alarm outputs, 12-28vdc, 110-240vac supply. |
|
|
|
analogue input - volume |
|
|
|
pulse/frequency input - mass |
|
|
|
analogue input - mass |
|
|
| |
|
pulse/frequency input - volume. Secure Batch Controller. field, panel or flameproof [EExd IIB T6] mounting, single flowmeter input, touch-key authorisation, dual relay outputs, modbus output, logging, ticket printing, pulse output, analogue output, alarm outputs, 12-28vdc, 110-240vac supply. |
|
|
| 515 Flow Computers - Gas |
Datasheet |
Manual |
|
general gas, pulse/frequency flow input, temperature and pressure inputs, field, panel or flameproof [EExd IIB T6] mounting, four relay outputs, modbus output, logging, ticket printing, pulse output, analogue output, 12-28vdc, 110-240vac supply. |
|
|
|
general gas, analogue flow input |
|
|
|
general gas, dp meter (mass span) |
|
|
|
general gas, dp meter (iso/cone) |
|
|
|
general gas, dp meter (volumetric span) |
|
|
| |
|
natural gas (aga8), quadrature flow input |
|
|
|
natural gas (aga8), analogue flow input |
|
|
|
natural gas (aga8), dp meter (mass span) |
|
|
|
natural gas (aga8), dp meter (iso/cone) |
|
|
|
natural gas (aga8), dp meter (aga3) |
|
|
|
natural gas (aga8), dp meter (volumetric span) |
|
|
|
natural gas (sgerg), quadrature flow input |
|
|
|
natural gas (sgerg), analogue flow input |
|
|
|
natural gas (sgerg), dp meter (mass span) |
|
|
|
natural gas (sgerg), dp meter (iso/cone) |
|
|
|
natural gas (sgerg), dp meter (volumetric span) |
|
|
| 515 Fow Computers - steam |
Datasheet |
Manual |
|
saturated and superheated steam , pulse/frequency flow input, temperature and pressure inputs, field, panel or flameproof [EExd IIB T6] mounting, four relay outputs, modbus output, logging, ticket printing, pulse output, analogue output, 12-28vdc, 110-240vac supply. |
|
|
|
analogue flow input |
|
|
|
dp meter (mass span) |
|
|
|
dp meter (iso/cone) |
|
|
|
dp meter (aga3) |
|
|
|
dp meter volumetric |
|
|
| 515 Flow Computers - Liquids |
Datasheet |
Manual |
|
add or subtract flow - volume, pulse/frequency input. field, panel or flameproof [EExd IIB T6] mounting, four relay outputs, modbus output, logging, ticket printing, pulse output, analogue output, 12-28vdc, 110-240vac supply. |
|
|
|
add or subtract flow - mass |
|
|
|
add or subtract flow - energy |
|
|
| |
|
net oil computer, pulse/frequency input - mass, temperature and density input |
|
|
| |
|
petroleum consumption, pulse/frequency flow input, dual temperature input |
|
|
|
petroleum consumption, analogue flow input, dual temperature input |
|
|
|
petroleum consumption, quadrature flow input, temperature and/or density input |
|
|
| |
|
pressurised petroleum flow, quadrature flow input, temperature/pressure/density compensation |
|
|
| 515 Flow Computer - Blending |
Datasheet |
Manual |
|
dual channel 2 stream blender, pulse/frequency input, field, panel and flameproof (EExd IIB T6) mounting, digital control valve outputs, 4 relay outputs, 4-20mA output, pulse output, modbus output, logging, ticket printing, 12-28vdc, 110-240vac supply. |
|
|
| 515 Flow Computer - Master Prover |
Datasheet |
Manual |
|
master meter proving for mass flowmeters, pulse/frequency flow input, field, panel and flameproof (EExd IIB T6), 4 relay outputs, 4-20mA output, pulse output, modbus output, logging, ticket printing, 12-28vdc, 110-240vac supply. |
|
|
|
 |
 |
 |
 |
|